Documentation
Tutorials
Workflows
Kebab actions
Daily Work
Dashboard & Reports
Quality Control
ISO 17025
Reagents & Storage
Logs
Contacts
Billing
Analysis Setup
Settings
Initial Setup
Help & Reference
Architecture decisions
Analysis Setup

Suppliers

The Suppliers page is the register of externally provided products and services: reagents, calibrations, reference materials, subcontractors, proficiency-test providers (ISO/IEC 17025 §6.6). The approval lifecycle implements §6.6.2, and calibration providers carry extra fields so an assessor can verify their accreditation against the date the work was done.

Found under: Analysis Configuration → Equipment → Suppliers.

Toolbar

ButtonAction
Add — Create a new record
Columns — Show/hide table columns
Filters — Open/close the filter panel. A red dot indicates active filters
Export CSV — Download table data as a CSV file
Orientation — Toggle between portrait and landscape printing
Print — Generate a PDF of the current view
Help — Open the help dialog
Search — Quick search through table data

Record Actions

Clicking the icon on each row shows:

  • Edit — Open the edit form
  • Delete — Delete the record (with confirmation)

Fields

FieldDescription
NameThe supplier's name — required
TypeWhat they provide — required, see below
StatusWhere they stand in the approval cycle; starts as Pending
Contact · Email · Phone · Website · Address · CountryContact details
Accreditation Body · Number · Scope · ExpiryThe evidence of an accredited provider's competence
Certificate URLPointer to the accreditation certificate
Evaluation Notes · NotesThe §6.6.2 evaluation and other remarks

Types

Reagent · Calibration · CRM (Certified Reference Material) · Service · Subcontractor · Proficiency Testing Provider · Interlaboratory Comparison Organiser · Equipment · Software · Other.

Statuses

StatusMeaning
PendingRegistered but not yet evaluated
ApprovedEvaluated and approved (§6.6.2)
SuspendedTemporarily out of use
RejectedNot used

Non-approved suppliers stay in the register so historical references do not break.

Connects to

Points at — this page does not stand without these:

Used by — a change here shows up in these:

If this is missing

  • §6.6.2: only approved suppliers may be used in new transactions. A suspended or

rejected supplier stays visible on purpose, so historical records pointing at it do not break.

  • 🔴 For calibration providers the critical field is the accreditation expiry. An assessor

checks whether the provider was accredited on the day the calibration was performed, not

today. An empty date means that question has no answer in the system.

  • A reference-material supplier with no certificate leaves the control sample with no traceability

to a national standard.

Notes

  • Status is handled in two ways, depending on where you are. Five pickers accept approved suppliers only: the two on reagents, a measurement's subcontractor, a control sample's certified material, and an instrument's calibration provider. Three others — shipments, external results, and proficiency testing — show a non-approved supplier marked "not approved" but still accept it.
  • ⚖️ The distinction is deliberate: hiding a non-approved supplier does not stop the laboratory using them in a hurry, it only stops the laboratory recording that it did. Clauses §7.5 and §8.4 care more about the record being true than about it being tidy.
  • Country and Accreditation Body suggest values you have already entered.
  • From Instruments, when no calibration provider exists, this page opens with the type pre-filled and a message explaining why.
  • 🔴 The date filters are labelled Created From/To but filter on Accreditation Expiry.