Workflows
0:000:00

Sample Workflow

This guide describes the step-by-step lifecycle of a sample — from reception and preparation, through linking to an analysis, result approval and report generation. The workflow follows ISO 17025 requirements for traceability, sample identification and chain of custody.


Prerequisites

Before creating a new sample, make sure the following data exists:

#PrerequisiteWhy it's neededPage
1ContactsEvery sample is linked to the customer who submitted it.Contacts
Recommended setup order: Contacts → Samples

Optional but useful:

  • Laboratory Methods — to log the analysis method
  • Instruments — to log the analytical instrument
  • Users — to record the collector / consultation officer in the chain of custody

Step 1 — Navigation

Go to the Samples page from the main menu. A table with existing samples is displayed.

The table columns are:

ColumnDescription
Sample CodeUnique identification code (e.g. SAM-YYYY-0001)
Receipt DateDate the sample was received at the laboratory
Delivery DateResults delivery deadline — shown in red if overdue
ContactThe contact (customer) who submitted the sample
StatusCurrent status in the workflow
MethodLaboratory method (optional)
InstrumentAnalytical instrument (optional)
PreparationPreparation status — drying / grinding / sieving (stars indicator)
NotesFree-text remarks
CropSampling crop (optional)
Municipality / City / ToponymSampling location (optional)

Step 2 — Sample Reception

Click the "+" button in the toolbar to open the reception form.

Fill in the fields:

  1. Sample Code — Leave blank for auto-numbering (SAM-YYYY-NNNN) or enter manually
  2. Receipt Date — Date the sample was received at the laboratory (required)
  3. Contact — Select the contact (customer) from the list (required)
  4. Status — Automatically set to Received on creation (not selectable here; becomes editable only later, while editing the sample)
  5. Lab Method — Analysis method (optional)
  6. Instrument — Analytical instrument (optional)
  7. Due Date — Results delivery deadline (optional)
  8. Notes — Additional remarks
  9. Photos — One or more sample photographs (file upload or camera capture)

The same form also includes a chain-of-custody section (§7.4), where the Condition on Arrival field is required. If its value is not "OK", recording a customer consultation (time, officer, outcome) is also required before the sample can be saved — see the Guide: Record a Customer Consultation (§7.4.3).

After saving, the sample is created in Received status and you can print a barcode label.

Batch Intake

Instead of entering samples one by one, the "Batch" button in the toolbar opens a batch-entry screen: paste from Excel (Ctrl+V), upload a CSV/TSV file, or scan barcodes, with row-by-row review/correction before the final save.

Barcode Label Printing

After creating the sample, you can print a barcode label (Code128 or QR) for physical identification. The label includes the sample code and can be scanned later for quick lookup.


Step 3 — Sample Preparation

Preparation is tracked through three steps, each with a checkbox and date:

StepFieldDateDescription
1DryingDrying DateDrying the sample in an oven
2GrindingGrinding DateGrinding/pulverizing the dried sample
3SievingSieving DateSieving to the desired particle size

Preparation status is shown in the table with star indicators (e.g. stars for 2 out of 3 steps completed).

Once all three steps are complete, change the status from In Preparation to In Analysis to begin measurement.

Step 4 — Linking to an Analysis

The analysis is not linked directly to the sample — it is linked to an Aliquot derived from the sample. Once the sample has been saved once, an Aliquots section appears on its edit form, where you create one or more aliquots (kind, purpose, container, preservation, storage location, etc.).

Once at least one aliquot exists:

  1. Go to the Analyses page (Analyses)
  2. Create a new analysis, selecting the aliquot (via the Select Aliquot field)
  3. The analysis is linked to the aliquot via FK — each analysis record corresponds to one aliquot
  4. Update the sample status to In Analysis
For the analysis workflow (entering measurements, review, approval), see the Analysis Workflow Guide.

Step 5 — Status Workflow

The sample follows a workflow with nine statuses:

StatusDescription
In CollectionRegistered in the field (via sampling) — has not yet reached the laboratory
ReceivedInitial state for samples arriving directly at the laboratory — or the sample was scanned at intake
In PreparationDrying, grinding or sieving is in progress
In AnalysisLinked to an analysis (via an aliquot), measurements are being entered
SubcontractedMeasurements have been sent to an external laboratory
AnalysedResults have been entered, pending review
ApprovedFinal approval — report can be generated (final state)
RejectedSample rejected (final state)
CancelledSample cancelled (final state)
The In Collection status only arises from field sampling. Samples registered via the page's "+" button (Step 2) start directly at Received.

Transitions

On the edit form, the Status field allows advancing or correcting by one step at a time (forward or backward), e.g. In Analysis ↔ In Preparation to fix a mistake:

In Collection → Received → In Preparation → In Analysis → (Subcontracted) → Analysed → Approved

Reject and Cancel are not done via the Status field — they are separate actions from the row's actions menu (⋮), with a mandatory reason, and are available from any status except the three final ones (Approved / Rejected / Cancelled):

ActionFromNote
RejectAny non-finalRequires a reason code; cascades to linked analyses
CancelAny non-finalRequires a reason (§8.4); blocked if the sample has aliquots with linked analyses — reject/cancel those first

Step 6 — Search & Filtering

Type in the search field for quick filtering by sample code or customer.

Barcode Scanner

Press the scan button in the toolbar to open the camera in fullscreen. Once a barcode or QR code is recognised, the system automatically looks up the matching sample and opens its edit form directly (not just a search/filter on the table).

Filter Panel

Click the filter icon to open the filter panel:

FilterTypeDescription
Date FromDateStart of receipt date range
Date ToDateEnd of receipt date range
ContactSelectFilter by contact (customer)
StatusSelectFilter by workflow status

Step 7 — Print & Export

ActionDescription
Print ListPrint the samples table as PDF
Export CSVExport data to a CSV file
Barcode LabelPrint a barcode label (Code128 or QR) for an individual sample

FAQ

How does auto-numbering work?

If you leave the sample code blank when creating, the system automatically assigns a code in the format SAM-YYYY-NNNN, where YYYY is the current year and NNNN is a sequential number.

Can I change the sample code after creation?

Yes, the sample code can be modified during editing, as long as it remains unique.

What is the sample-analysis relationship?

Each analysis record is linked to one aliquot, not directly to the sample. The sample records the physical reception and preparation, aliquots are derived from the sample, and the analysis — linked to one aliquot — records the measurements, evaluations and report generation.

What do the stars in the Preparation column mean?

The stars indicate how many of the 3 preparation steps (drying, grinding, sieving) have been completed. For example, two filled stars out of three means 2 of 3 steps are complete.

Why is the delivery date shown in red?

If the results delivery deadline has passed, the date is displayed in red bold as a visual alert.

How do I scan a sample barcode?

Press the scan button in the toolbar (opens the camera in fullscreen) and aim at the barcode or QR code. The system automatically looks up the sample with the corresponding code and opens its form.


See also