This guide describes the step-by-step process for creating and managing worklists. Worklists group samples by lab method or instrument for more efficient batch processing.
Before you begin, make sure the following data exists:
| # | Prerequisite | Why it's needed | Page |
|---|---|---|---|
| 1 | Samples | Received samples are needed to add to the worklist. | Samples |
| 2 | Lab Methods | Each worklist is linked to a lab method. | Lab Methods |
Tip: Create samples first and ensure their status is "Received" before adding them to a worklist.
Go to the Worklists page from the main menu. A table of existing worklists is displayed.
The visible table columns are:
| Column | Description |
|---|---|
| Name | Title of the worklist |
| Date | Creation date |
| Lab Method | The laboratory method |
| Status | Open or Closed |
| Samples | Number of samples in the worklist |
Click the "+" button on the toolbar to open the creation form.
Fill in the fields:
After saving, open the worklist in edit mode. Below the basic fields, the "Samples" section appears.
Click "Add Samples" to select samples from the list. You can add multiple samples at once.
Samples are displayed with their code, client and reception date.
When the worklist has samples and the method defines elements, a measurement grid (bench-sheet) appears: rows = samples, columns = the method's elements. Every method column stays visible so you can key across the whole grid.
Key values fast directly in the cells, without the mouse:
6,8 or 6.8)As soon as you edit a cell, the "Save Measurements" button appears (with an "Unsaved changes" hint). Click it to save the whole grid.
Saving runs the ISO 17025 checks — e.g. if an instrument doesn't meet requirements (calibration/verification overdue, §6.4), the save is blocked and the blocking instrument is shown inline in the dialog.
Alternatively, "Import Measurements" loads values from a file or paste.
After all samples have been processed, change the status to "Closed". A closed worklist serves as a historical record.
Type in the search field for quick text filtering.
Click the filter icon to open the filter panel:
| Filter | Type | Description |
|---|---|---|
| Status | Select | Open or Closed |
| Lab Method | Select | Show worklists for a single method only |
| Date From | Date | Range start date |
| Date To | Date | Range end date |
| Max Records | Number | Record limit for print/export (default: 200) |
Can a sample be in multiple worklists?
Yes, a sample can belong to multiple worklists — for example one for ICP and one for AAS, if different analysis methods are required.
How do I reopen a closed worklist?
Open the worklist in edit mode and change the status from "Closed" to "Open".
What happens if I remove a sample from a worklist?
Removing a sample from a worklist does not affect the sample's data or its measurements. Only the link is removed.
Do I have to close worklists?
It is not mandatory, but recommended. Closed worklists serve as a record of completed batches.